DL-U18 1800 GPD Tankless RO System

The DL-U18 is an 1800 GPD tankless RO system for high-demand home kitchens. Dual RO membranes reuse concentrate and combine purified-water output, delivering approximately 4.2 L/min for drinking and cooking.

  • 1800 GPD with approx. 4.2 L/min purified-water flow
  • Dual RO membranes with concentrate reuse
  • Three cartridges providing four functional filtration stages
  • Separate filtered-water and RO purified-water outputs

1800 GPD

Dual RO

Tankless

Dual Outputs

OEM/ODM options include branding, faucets, external modules and packaging. Choose 1800 GPD with two 900 GPD membranes or 1600 GPD with two 800 GPD membranes.

Product Overview

Cutaway illustration showing water flowing through two RO membranes

Dual-Membrane Direct Flow

The 1800 GPD configuration combines two RO membranes to provide approximately 4.2 L/min of purified water, supporting household demand without a separate storage tank.

Close-up illustration of the DL-U18 internal water channels beside its two RO membranes

Concentrate Reuse

Concentrate from the first RO membrane feeds the second for further treatment. Purified water from both membranes is collected together and passes through post-carbon polishing before dispensing.

Illustration of water passing through multiple filtration layers

Four-Stage Filtration

The filtration layout combines PAF pretreatment, concentrate treatment across two RO membranes and post-carbon polishing. Three replaceable cartridges provide four functional stages for drinking and cooking.

Dual-outlet faucet illustrating pre-filtered water for washing vegetables and RO purified water for drinking

Separate Water Outlets

Separate outlets supply pre-filtered water for washing fruit, vegetables and kitchen items, and RO purified water for drinking, making tea, preparing coffee and cooking.

Compare the core functions above, then explore the membrane layout, installation and maintenance details below.

Explore the dual-membrane water path, cartridge access and installation features of the DL-U18 tankless RO system.

Cutaway illustration of a spiral-wound reverse osmosis membrane

Cascaded RO Water Path

After PAF pretreatment, feed water enters the first RO membrane. Its concentrate then feeds the second membrane, while purified water from both membranes joins the final drinking-water path.

Activated carbon filter illustration showing porous carbon material and water flow

PAF Pretreatment & Polishing

The PAF composite cartridge contains separate pretreatment and post-carbon sections. Water passes through pretreatment before RO filtration, then returns to the post-carbon section before dispensing.

Close-up of the DL-U18 with RO cartridges partially withdrawn for replacement

Easy Filter Replacement

Slide-out, quick-change cartridges simplify routine maintenance. The PAF cartridge and two RO membranes can be replaced individually, with accessible installation space allowing convenient servicing.

Close-up of the DL-U18 water connection ports on the rear housing

High-Flow Water Connections

The 3/8-inch water path supports higher flow for kitchen use. Separate filtered-water and RO outlets connect to a compatible faucet, with space required for tubing, drainage and routine servicing.

DL-U18 with its front cover removed, showing three individually replaceable filter cartridge handles

Replacement Planning

Reference replacement intervals are 3–6 months for PAF, around three years for RO1 and around one year for RO2. The membranes handle different feed-water loads and are serviced individually.

Cutaway illustration showing the three filter cartridges and internal water path of the DL-U18

Standby Auto-Flushing

After extended idle periods, automatic flushing replaces water held inside the RO membranes. This helps reduce the TDS rise in the first draw when the system returns to use.

Configure the DL-U18 for your household water-filtration range. Share your target market, kitchen water needs and installation requirements to review capacity, faucet options, branding and packaging.

DL-U18 tankless RO systems displayed in different housing colors for OEM branding customization

Logo & Branding

Customize housing colors and logo placement to match your brand, with available finishes, artwork and printing options reviewed before production.

Drinking-water faucet with a digital display dispensing water into a glass

Faucet Options

Choose a mechanical dual-outlet faucet or an optional display faucet, with TDS and filter-reminder functions matched to the selected configuration.

External remineralization cartridge and flow-through UV module for RO system expansion

External Modules

Extend the system with an external remineralization cartridge or a flow-through UV module to support additional water-treatment functions for your project.

Custom packaging box design examples

Packaging & Market

Customize packaging artwork and instructions for your market, with electrical specifications, plug and power-cord options confirmed for the destination.

Technical Specifications

Parameter
Specification
Model
DL-U18
Dimensions (W × D × H)
150 × 430 × 430 mm
Reference configuration
1800 GPD
Optional configuration
1600 GPD
RO membrane configuration
1800 GPD: 2 × 900 GPD; 1600 GPD: 2 × 800 GPD
Purified-water flow rate
Approx. 4.2 L/min with the 1800 GPD configuration
Filtration
Four functional filtration stages
Cartridge configuration
Three cartridges: one PAF composite cartridge and two RO membranes
PAF cartridge functions
Pretreatment and post-carbon polishing
Dual-membrane water path
RO1 concentrate feeds RO2; purified water from both membranes is collected together
Water outputs
Separate filtered utility water and RO purified water
Pure-to-drain ratio
Approx. 2.5–3:1
Water path
3/8-inch high-flow water path
Operating noise
Approx. 40 dB(A)
Faucet options
Mechanical dual-outlet faucet or optional display faucet
Optional faucet functions
TDS display and filter-life reminders, depending on configuration
Recommended replacement intervals
PAF: 3–6 months; RO1: approx. 3 years; RO2: approx. 1 year

Flow figures refer to the 1800 GPD configuration. Actual flow, pure-to-drain ratio, noise and filter life vary with feed-water quality, TDS, hardness, temperature, pressure, usage and operating conditions. Replacement intervals are reference recommendations rather than guaranteed service life.

More About Driplife

Learn about Driplife and our approach to water filtration product development, manufacturing and OEM/ODM cooperation for brands and distributors.

Interested in the DL-U18?

Planning a dual-membrane tankless RO product for high-demand home kitchens? Share your target market, preferred capacity, faucet functions and branding requirements. We can review DL-U18 samples, configuration options and a project quotation.

We provide OEM and ODM development for water filtration systems, helping global brands and distributors build reliable products and customized solutions.

Let’s Start Your Water Filtration Project

healthy drinking water lifestyle concept