Share:
DL-U18 · TANKLESS RO SYSTEMS
DL-U18 1800 GPD Tankless RO System
The DL-U18 is an 1800 GPD tankless RO system for high-demand home kitchens. Dual RO membranes reuse concentrate and combine purified-water output, delivering approximately 4.2 L/min for drinking and cooking.
- 1800 GPD with approx. 4.2 L/min purified-water flow
- Dual RO membranes with concentrate reuse
- Three cartridges providing four functional filtration stages
- Separate filtered-water and RO purified-water outputs
1800 GPD
Dual RO
Tankless
Dual Outputs
OEM/ODM options include branding, faucets, external modules and packaging. Choose 1800 GPD with two 900 GPD membranes or 1600 GPD with two 800 GPD membranes.
Product Overview

Dual-Membrane Direct Flow
The 1800 GPD configuration combines two RO membranes to provide approximately 4.2 L/min of purified water, supporting household demand without a separate storage tank.

Concentrate Reuse
Concentrate from the first RO membrane feeds the second for further treatment. Purified water from both membranes is collected together and passes through post-carbon polishing before dispensing.

Four-Stage Filtration
The filtration layout combines PAF pretreatment, concentrate treatment across two RO membranes and post-carbon polishing. Three replaceable cartridges provide four functional stages for drinking and cooking.

Separate Water Outlets
Separate outlets supply pre-filtered water for washing fruit, vegetables and kitchen items, and RO purified water for drinking, making tea, preparing coffee and cooking.
Compare the core functions above, then explore the membrane layout, installation and maintenance details below.
A Closer Look
Explore the dual-membrane water path, cartridge access and installation features of the DL-U18 tankless RO system.

Cascaded RO Water Path
After PAF pretreatment, feed water enters the first RO membrane. Its concentrate then feeds the second membrane, while purified water from both membranes joins the final drinking-water path.

PAF Pretreatment & Polishing
The PAF composite cartridge contains separate pretreatment and post-carbon sections. Water passes through pretreatment before RO filtration, then returns to the post-carbon section before dispensing.

Easy Filter Replacement
Slide-out, quick-change cartridges simplify routine maintenance. The PAF cartridge and two RO membranes can be replaced individually, with accessible installation space allowing convenient servicing.

High-Flow Water Connections
The 3/8-inch water path supports higher flow for kitchen use. Separate filtered-water and RO outlets connect to a compatible faucet, with space required for tubing, drainage and routine servicing.

Replacement Planning
Reference replacement intervals are 3–6 months for PAF, around three years for RO1 and around one year for RO2. The membranes handle different feed-water loads and are serviced individually.

Standby Auto-Flushing
After extended idle periods, automatic flushing replaces water held inside the RO membranes. This helps reduce the TDS rise in the first draw when the system returns to use.
Configuration & Customization
Configure the DL-U18 for your household water-filtration range. Share your target market, kitchen water needs and installation requirements to review capacity, faucet options, branding and packaging.

Logo & Branding
Customize housing colors and logo placement to match your brand, with available finishes, artwork and printing options reviewed before production.

Faucet Options
Choose a mechanical dual-outlet faucet or an optional display faucet, with TDS and filter-reminder functions matched to the selected configuration.

External Modules
Extend the system with an external remineralization cartridge or a flow-through UV module to support additional water-treatment functions for your project.

Packaging & Market
Customize packaging artwork and instructions for your market, with electrical specifications, plug and power-cord options confirmed for the destination.
Technical Specifications
Parameter | Specification |
|---|---|
Model | DL-U18 |
Dimensions (W × D × H) | 150 × 430 × 430 mm |
Reference configuration | 1800 GPD |
Optional configuration | 1600 GPD |
RO membrane configuration | 1800 GPD: 2 × 900 GPD; 1600 GPD: 2 × 800 GPD |
Purified-water flow rate | Approx. 4.2 L/min with the 1800 GPD configuration |
Filtration | Four functional filtration stages |
Cartridge configuration | Three cartridges: one PAF composite cartridge and two RO membranes |
PAF cartridge functions | Pretreatment and post-carbon polishing |
Dual-membrane water path | RO1 concentrate feeds RO2; purified water from both membranes is collected together |
Water outputs | Separate filtered utility water and RO purified water |
Pure-to-drain ratio | Approx. 2.5–3:1 |
Water path | 3/8-inch high-flow water path |
Operating noise | Approx. 40 dB(A) |
Faucet options | Mechanical dual-outlet faucet or optional display faucet |
Optional faucet functions | TDS display and filter-life reminders, depending on configuration |
Recommended replacement intervals | PAF: 3–6 months; RO1: approx. 3 years; RO2: approx. 1 year |
Flow figures refer to the 1800 GPD configuration. Actual flow, pure-to-drain ratio, noise and filter life vary with feed-water quality, TDS, hardness, temperature, pressure, usage and operating conditions. Replacement intervals are reference recommendations rather than guaranteed service life.
More About Driplife
Learn about Driplife and our approach to water filtration product development, manufacturing and OEM/ODM cooperation for brands and distributors.
Explore Related Models

DL-U10
A compact 1000 GPD tankless RO system for home kitchens, with a 126 mm slim body, dual water outputs and an optional TDS-display faucet.

DL-U20
A 2000 GPD tankless under-sink RO system with approximately 5.2 L/min reference flow for small commercial sites and equipment water-supply projects.
Interested in the DL-U18?
Planning a dual-membrane tankless RO product for high-demand home kitchens? Share your target market, preferred capacity, faucet functions and branding requirements. We can review DL-U18 samples, configuration options and a project quotation.














