Share:
DL-U20 · TANKLESS RO SYSTEMS
DL-U20 2000 GPD Tankless RO System
The DL-U20 is a compact 2000 GPD tankless RO system for under-sink installation. Its single high-capacity RO membrane provides a reference continuous purified-water flow of approximately 5.2 L/min without a separate pressure storage tank. Designed for higher-demand small commercial sites and equipment water-supply projects.
- Single 2000 GPD RO membrane; reference continuous flow of approximately 5.2 L/min
- Under-sink installation without a separate pressure storage tank
- Two cartridges providing three functional filtration stages
- Separate pre-filtered water and RO purified-water outputs
2000 GPD
High Flow
Tankless
Dual Outputs
OEM/ODM options for the DL-U20 include branding, faucet selection, external add-on modules and packaging. Share your market and installation requirements to review the configuration, plug and power-cord options.
Product Overview

Tankless Direct Flow
This 2000 GPD tankless RO system delivers approximately 5.2 L/min of purified water directly, without a separate pressure storage tank.

TDS Display & Controls
The front panel brings together a TDS display, filter-status indicators and controls for flushing, filtration and reset in one operating area.

Three-Stage Filtration
Three-stage filtration combines PPC pretreatment, reverse osmosis and post-carbon polishing for drinking, coffee, tea and cooking.

Separate Water Outlets
Separate outlets supply pre-filtered water for washing and kitchen cleaning, and RO purified water for drinking and food preparation.
Compare the core functions above, then review dispensing, installation and service details below.
A Closer Look
Explore the single-membrane filtration path, water connections and service access of this 2000 GPD tankless reverse osmosis system.

Single 2000 GPD RO Membrane
A single high-capacity 2000 GPD RO membrane supports direct-flow production for restaurants, cafés and small commercial kitchens, with approximately 5.2 L/min of reference continuous purified-water output.

PPC Pretreatment & Polishing
The PPC cartridge provides pretreatment before the RO membrane. Purified water then passes through a separate post-carbon section inside the same cartridge for final taste polishing before dispensing.

Easy Filter Replacement
Front-access cartridges simplify routine replacement without moving the entire unit. Use the cartridge wrench to release the filter, then remove and replace it through the front service opening.

Water Connections
The feed-water inlet and both product-water outlets use 3/8-inch connections. Wastewater and auxiliary ports use 1/4 inch. The auxiliary outlet supports connections to compatible external equipment.

Replacement Planning
Recommended intervals are 3–6 months for PPC and 6–12 months for RO. Plan replacement cartridge supplies around local water quality, daily consumption and the intended application.

Tankless Under-Sink Design
The 155 × 460 × 415 mm (W × D × H) body fits beneath the counter without a separate pressure storage tank. Reserve access for ventilation, water connections and front-access cartridge replacement.
Configuration & Customization
Configure the DL-U20 tankless RO system for your product range or equipment-supply project. Share your target market, water demand and installation conditions to review branding, faucet options, external modules and packaging.

Logo & Branding
Customize logo placement on the housing and cartridges to match your brand, with artwork and printing options reviewed before production.

Faucet Options
Choose mechanical dual-outlet or display-faucet options, with faucet style and display functions selected for your market and installation.

External Modules
Expand the system with an external remineralization cartridge or flow-through UV module to add the functions required for your project.

Packaging & Market
Customize packaging artwork and instructions for your market, with plug and power-cord options matched to the destination requirements.
Technical Specifications
Parameter | Specification |
|---|---|
Model | DL-U20 |
Dimensions (W × D × H) | 155 × 460 × 415 mm |
Rated membrane capacity | 2000 GPD |
Purified-water flow rate | Approx. 5.2 L/min |
Filtration | PPC pretreatment, RO filtration and post-carbon polishing |
Cartridge configuration | Two cartridges: one PPC cartridge and one 2000 GPD RO membrane |
Water outputs | Separate pre-filtered water and RO purified water |
Pure-to-drain ratio | Approx. 2.5:1–3:1 |
Rated power input | 200 W |
Feed-water source | Municipal tap water |
Feed-water pressure | 0.1–0.4 MPa |
3/8-inch connections | Feed-water inlet, pre-filtered water outlet and RO purified-water outlet |
1/4-inch connections | RO wastewater outlet and auxiliary outlet for connection to external equipment |
Ambient temperature | 4–40°C |
Filter replacement | Front-access quick-change cartridges |
Recommended replacement intervals | PPC: 3–6 months; RO membrane: 6–12 months |
The 2000 GPD figure is the membrane’s rated capacity. Actual purified-water flow, pure-to-drain ratio and filter replacement intervals depend on feed-water quality, temperature, pressure, water consumption and operating conditions.
More About Driplife
Learn about Driplife and our approach to water filtration product development, manufacturing and OEM/ODM cooperation for brands and distributors.
Explore Related Models

DL-U10
A compact 1000 GPD tankless RO system for home kitchens, with a 126 mm slim body, dual water outputs and an optional TDS-display faucet.

DL-U18
An 1800 GPD dual-membrane tankless RO system for high-demand home kitchens, with concentrate reuse and approximately 4.7 L/min purified-water flow.
Interested in the DL-U20?
Planning a 2000 GPD tankless RO project? Share your target market, daily and peak water demand, feed-water conditions and equipment inlet requirements. We can review DL-U20 suitability, samples, configuration options and a project quotation.












